Anti-static shoes are used to prevent static electricity, and insulated shoes are used to prevent electric shock, so how to distinguish them?

In general, those with a resistance greater than 1012Ω are insulated, while those with a resistance greater than 106 and less than 1012 are antistatic. Insulating rubber is non-conductive, anti-static rubber is conductive, but the resistance value is relatively large, the standard requirement is between 106 and 109. Anti-static rubber is mostly used in the electronics industry. During use, friction does not generate static electricity, which plays a role in protecting electronic products.
    Anti-static slippers are made of insulating rubber and are generally used in electrical installations to prevent electric shock. Anti-static slippers have a weak conductive function, which can lead the excess charge of the human body through it to the human body and guide it to the ground, avoiding the accumulation of charge and generating electrostatic discharge, thus eliminating the static electricity of the human body.
Insulating shoes are made of non-conducting insulating material, which isolates the person from the ground, so that even if the person is in contact with the conductive body, there will be no accident of the current passing through the body and entering the ground.
    Anti-static is a coefficient index between insulation and conductivity. Anti-static shoes can be worn by most people, especially in the northern regions. In winter, the air is dry, and static electricity is easy to accumulate on people. Wearing anti-static shoes can prevent people from being hit by static electricity. Anti-static shoes are used to prevent accidents caused by sparks caused by static electricity. It is to add anti-static shoes and conductive wire to the sole of the shoe, which can lead the static electricity accumulated by the person to the ground. Generally used in special gas, petroleum, petrochemical and other flammable and explosive places. Because it is mainly used to discharge the static electricity generated by the human body, anti-static shoes are not only used in the petrochemical industry, but also widely used in electronic companies such as precision electronics and components, optical instruments, pharmaceutical companies and so on.
Insulated shoes can only be used by maintenance electricians at work to reduce the risk of electric shock. It is generally worn by electricians to prevent electric shocks due to stepping voltages and to prevent electric shocks due to ground conduction.